Aerobika ARX

AEROBIKA* OPEP Device with Arx* Connected Technology

For drug-free therapy or can be used with a nebulizer
Bronchiectasis
COPD
Cystic Fibrosis
Drug Free
Nebulized Medication

Why use this device?

The AEROBIKA* Oscillating Positive Expiratory Pressure (OPEP) device is a drug-free and easy to use device that can help clear excess mucus in the airways and improve breathing.1
 
ARX* Connected Technology can help AEROBIKA* device users improve their technique with real-time LED feedback. The ARX* ring light coaches the user to exhale more softly or more forcefully to generate the right amount of expiratory pressure and oscillations to assist in airway clearance.
 
When an ARX* device is paired with the AEROLIV* mobile app, you can automate treatment reminders, visualize your progress over time and share your progress with your healthcare provider.
 
The AEROBIKA* device has an innovative pressure-oscillation mechanism that creates positive pressure pulses when a patient exhales. The positive pressure created can assist with opening weak or collapsed airways.1 The AEROBIKA* device also produces vibrations in the airways that can help to thin and loosen mucus, naturally moving it to the upper airways where it can be coughed out easily.2
 
The AEROBIKA* device can be used to manage respiratory conditions such as COPD, Bronchiectasis, and Cystic Fibrosis.
 
For more information, news, and reminders, sign up for: myAero Community
 

1. Svenningsen S, Paulin GA, Sheikh K, et al. Oscillatory Positive Expiratory Pressure in Chronic Obstructive Pulmonary Disease. COPD. 2016;13(1):66-74.

2. Jean Bourbeau, R. Andrew McIvor, Hollie M. Devlin & Alan Kaplan (2019): Oscillating positive expiratory pressure (OPEP) device therapy in Canadian respiratory disease management: Review, care gaps and suggestion for use, Canadian Journal of Respiratory, Critical Care, and Sleep Medicine, DOI: 10.1080/24745332.2018.1558426


 
Currently this is not available for purchase through this website.

How does the AEROBIKA* ARX* device work?

• Real-time feedback encourages you to exhale with the correct technique, every time you use the device.

 

Why Pair with the AEROLIV* App

• Reminders and treatment history encourage you to complete your treatments as prescribed to stay on track
• Create customizable medication reminders so you don't forget to use your puffers, pills or other treatments.
• Track your symptoms overtime and spot trends
• Add your daily peak flow measurements to track your lung function over time
• See your treatment stats, at a glance
• Share your progress in PDF reports
• Learn more about respiratory condition management with our curated and trusted resources

How to Use an AEROBIKA* OPEP Device with Arx* Connected Technology

Follow the steps outlined below or download our full instructions

Before use, ensure these instructions, and those for the Aerobika* OPEP device, have been read and are kept available at all times. If you have questions about the performance or use of this product, please contact your healthcare professional prior to use.

Getting Started

1. Remove all the pieces from the package.

2. Remove the mouthpiece from the Aerobika* device.

3. Attach the mouthpiece to the Adaptor. It will only fit on one end.

4. Attach the Aerobika* device to the other end of the Adaptor.

Activate the Module

1. To turn on for the first time, press and hold the button on the top of the Module until the light ring lights up. This will take approximately 3 seconds.

2. Let go of button once lights appear. 

  • If the device doesn’t light up after 10 seconds, the battery may be dead
  • You will need to charge your device before you can record your first airway clearance therapy session.

3. The device is now “awake” and is ready to use when the front of the ring pulses a soft blue light. 

  • If the device displays an amber pulse at the front of the light ring, the device’s battery needs to be charged.
  • You can still perform an airway clearance therapy session, and the device will track your performance. However, to conserve the battery, it will not provide visual feedback.

4. The device will go to sleep after idling for 30 seconds and the blue light will turn off. When the device is picked up or moved, the blue light will pulse to indicate it is “awake” again.

5. Your Arx* device is now ready to use. It will record several days of therapy data but will need to be paired with your phone to download data. To pair with your phone, please see the next section.

Using your Arx* Connected Technology with the AeroLiv* Mobile App

AeroLiv* is a mobile application available on both Apple and Android devices. To learn more about the app and to begin using it with your Arx* device visit aeroliv.ca

Using the Aerobika* Arx* Device

1. The assembled device can be used in any orientation. It is recommended that treatments be done in a comfortably seated position

2. Pick up the Aerobika* Arx* device. The device will automatically calibrate each time it “wakes up” so wait for the blue pulse before beginning your treatment. 

  •  If the blue pulse does not appear, your device may be in Travel Mode, or the battery may require charging.
  • If you start to exhale into the device before the light pulse reappears, your device has not had time to calibrate and will not record your airway clearance therapy session. Place the device back on a flat surface and wait for the light pulse to reappear, this should only take 1-2 seconds.

3. Follow the steps included in the Aerobika* device instructions for use for additional guidance on completing an airway clearance treatment.

4. The goal of each breath is to see green on the light ring. This indicates you are exhaling through the device within the desired range. 

  • If you are exhaling too softly, a solid blue light will appear in the front of the light ring. To correct your technique, exhale more forcefully with a firm steady breath until the light ring turns green.
  • If you are exhaling too hard, the light ring will flash red. To correct your technique, exhale softer until the light ring turns green.

5. When you see the green lights move in a circular pattern you have reached your treatment time or breath-count goal. The pattern will repeat after each additional exhalation.

Cleaning an AEROBIKA* OPEP Device with Arx* Connected Technology

Follow the steps outlined below or download our full instructions

  • The Electronic Module contains electronic components and CANNOT be put in water, boiled, microwaved, or steamed.
  • Proper and regular cleaning of the Arx* device is important for correct operation.

Disassembly

You must separate the Aerobika* device and Arx* device into components before cleaning.

1. Remove the Aerobika* body from the Adaptor.

2. Hold the Adaptor, with the Mouthpiece facing away from you.

3. To remove the Electronic Module, grip firmly and rotate counterclockwise while pulling away from the Adaptor

4. Remove the Mouthpiece from Adaptor.

5. The green silicone membrane should be loosened from its attachment point but remain attached to the Adaptor during cleaning

6. Follow the disassembly instructions included with your Aerobika* device.

Cleaning Procedure

1. The Adaptor should be cleaned whenever you clean your Aerobika* device. It can be cleaned by handwashing in a warm water/liquid dish detergent solution, rinsed with clean water and shaken to remove any excess.

2. The outer surface of the Electronic Module can be wiped with a damp (not wet) alcohol swab and air dried. 

  • To create an alcohol swab, add 70% isopropyl alcohol to a sterile cotton swab or use a sealed store-bought alcohol wet wipe

3. Ensure the Adaptor is completely dry before reattaching the Electronic Module.

4. Follow the cleaning instructions included with your Aerobika* device.

Complete Assembly of Arx* and Aerobika* devices after cleaning

1. Reattach the Mouthpiece to the front of the Adaptor.

2. Attach the Aerobika* body to the other end of the Adaptor.

3. Reseat the green silicone membrane you loosened prior to cleaning on the circular port on the top of the Adaptor.

4. Reattach the Electronic Module following the steps in Figure 3 in reverse order. Align the Electronic Module to the Adaptor port and attach it to the Adaptor. The two pieces will not fit together unless you have the Electronic Module angled correctly.

5. Once the two circular ports are engaged, gently rotate the Electronic Module clockwise until it is inline with the Adaptor, and it is firmly locked in place. Do not overtighten.

6. The device is now ready to use.

Reimbursement Information

How to be reimbursed for the cost of the AEROBIKA* OPEP Device?

AEROBIKA* OPEP Testimonials

Recommended Solutions

AeroEclipse XL without attached tubing viewed from the right

AEROECLIPSE* XL BAN* Nebulizer

Breath Actuated delivery for true on-demand therapy

6 months, reusable – ideal for the home environment.

Ombra tabletop compressor shown with the AEROECLIPSE* XL BAN* Nebulizer

OMBRA* Table Top Compressor

For use with AEROECLIPSE* BAN* Nebulizers

The OMBRA* Table Top Compressor system is easy to use and durable for treatments at home.

Truzone peak flow meter viewed on an angle

TRUZONE* Peak Flow Meter

Standalone drug-free device

A portable and inexpensive device that is used to measure how well air moves out of your lungs.