AEROCHAMBER* mini Anti-Static Holding Chamber

For use with an MDI for mechanically ventilated patients
Asthma Management
Bronchiectasis
COPD
Cystic Fibrosis
Inhaler

The AEROCHAMBER* mini Anti-Static Holding Chamber can be used in a ventilator circuit or with a resuscitation bag. Compact, the chamber minimizes dead space. This chamber is removed from the circuit following treatment.

  • Small volume chamber suitable for application in neonates and other patients with lower tidal volumes
  • Anti-static improves the reliability of medication delivery1
  • Ready to use directly out of the package – time saving with no pretreatment needed

1. Jason Suggett, et al. Use Of Valved Holding Chambers Without Pre-conditioning And The Influence Of Anti-static Materials. Journal of Aerosol Medicine and Pulmonary Drug Delivery 2014;28.

Currently this is not available for purchase through this website.

Why is an inhaler always together with an AEROCHAMBER* mini spacer?

Use of a spacer simplifies coordination of MDI actuation and inhalation, reducing aerosol losses with poor hand-breath coordination.2

2. Douglas S Gardenhire, et al. A Guide To Aerosol Delivery Devices for Respiratory Therapists, 5th Edition. American Association for Respiratory Care 2023. 


Features

  • AERODOCK* Canister Port and a removable canister adaptor allows for use with all types of metered dose inhalers, including those with integrated dose counters
  • 15mm connector fits standard endotracheal tubes
  • Separate exhalation channel minimizes dead space for low tidal volume patients
  • Single-patient use, multiple use (replace with the circuit)
labelled diagram of aerochamber mini

A 15 mm Endotracheal Tube Connector | B Wye Connector | C Canister Port | D Canister Adapter

Image
diagram showing how to connect aerochamber mini

Step 1

Disconnect the wye from the endotracheal tube. Connect the 15 mm endotracheal tube connector (A) to the endotracheal tube. Connect the wye connector (B) to the wye. The arrow on the chamber must point towards the patient and the canister port (C) must be on top.

Image
diagram depicting how to remove mdi canister from GSK mdi device

Step 2

If using a GlaxoSmithKline† type MDI canister with integrated dose counter, remove the canister adapter (D) from the unit. For all other canisters leave the canister adapter (D) in the port.

Image
Aerochamber MV-Product-Illustration-Ventilator-Circuit-How-To-Use-3

Step 3

Shake the MDI canister immediately before use as per the instructions supplied with the MDI. Insert the MDI canister into the canister port (C), being careful not to discharge the canister at this time. The integrated counter in GlaxoSmithKline† type MDI canister will be functional upon actuation.

Image
erochamber MV-Product-Illustration-Ventilator-Circuit-How-To-Use-4.

Step 4

Hold the canister in a vertical position. Prior to the beginning of inspiration, actuate the canister

Image
diagram showing how to remove mdi canister from aerochamber mini

Step 5

Following treatment, remove the MDI canister from the chamber. Disconnect the chamber from the endotracheal tube and from the wye. Reconnect the wye to the endotracheal tube. Store in a clean, dry place when not in use.


Cleaning

The device should not be cleaned. It can be replaced with the ventilator circuit. Refer to the instructions for use for additional information.

diagram depicting how to use aerochamber mini with resuscitation bag

A 15 mm Endotracheal Tube Connector | B Wye Connector | C Canister Port | D Canister Adapter

Image
diagram depicting how to attach resuscitation bag to aerochamber mini

Step 1

Attach the resuscitation bag to the wye connector (B).

Image
diagram showing how to disconnect the wye from the endotracheal tube

Step 2

Disconnect the wye from the endotracheal tube. Connect the 15 mm endotracheal tube connector (A) to the endotracheal tube. The arrow on the chamber must point towards the patient and the canister port (C) must be on top.

Image
diagram depicting how to remove canister adapter for GSK MDI canister

Step 3

If using a GlaxoSmithKline† type MDI canister with integrated dose counter, remove the canister adapter (D) from the unit. For all other canisters leave the canister adapter (D) in the port.

Image
Aerochamber MV-Product-Illustration-Resucitation-How-To-Use-4

Step 4

Shake the MDI canister immediately before use as per the instructions supplied with the MDI. Insert the MDI canister into the canister port (C), being careful not to discharge the canister at this time. The integrated counter in GlaxoSmithKline† type MDI canister will be functional upon actuation.

Image
Aerochamber MV-Product-Illustration-Resucitation-How-To-Use-5

Step 5

Hold the canister in a vertical position. Actuate the canister and immediately deliver a manual breath.

Image
diagram depicting how to remove MDI canister from aerochamber mini

Step 6

Following treatment, remove the MDI canister from the chamber. Disconnect the chamber from the endotracheal tube. Reconnect the wye to the endotracheal tube. Store in a clean, dry place when not in use.

Cleaning

The device should not be cleaned. It can be replaced with the ventilator circuit. Refer to the instructions for use for additional information.

Scientific & Performance Evidence

Trudell Medical International has an enviable history of strong leadership in creating innovative medical devices that enhance the quality of life for people of all ages - all backed by science and clinical evidence.


In Vitro Evaluation Of A Novel Ventilation Chamber (VC) For Delivery Of Aerosolized Medication To The Mechanically Ventilated Premature Infant

In vitro study reports delivery of albuterol with the AeroChamber* mini Anti-Static Holding Chamber.

Download


Specialty Chambers Study Summary

A study compilation covering the full range of specialty application chambers that have been designed to deliver metered dose inhaler (MDI) aerosol medication within the hospital environment.

Download

Product Information

For more detailed instructions on how to care for your device, download our printables.


AEROCHAMBER* mini Anti-Static Holding Chamber Instructions for Use

Instructions for use.

Download


AEROCHAMBER* VENT Holding Chamber Product Information Sheet

Refer to the instructions for use for additional information.